EIS Data Analysis for Ceramic Electrolytes
From impedance to transport properties.
Convert a fitted resistance into ionic conductivity using the sample geometry, then estimate an apparent activation energy from temperature-dependent conductivity data. Enter your own values; all calculations run locally in your browser.
Conductivity from resistance
The geometry factor is L/A. Convert millimetres consistently before calculating; the tool performs the conversion to centimetres.
Activation energy from σ(T)
For a thermally activated process represented by σT = σ₀ exp(−Eₐ/kBT), the slope of ln(σT) against 1/T is −Eₐ/kB.
This is a two-point estimate. Use multiple temperatures and linear regression for a defensible activation energy.
Arrhenius regression
Enter at least three temperature–conductivity pairs. The tool fits ln(σT) = intercept + slope × (1/T), reports R² and calculates Eₐ = −slope × kB.
| Point | Temperature (°C) | σ (S cm⁻¹) |
|---|---|---|
| 1 | ||
| 2 | ||
| 3 | ||
| 4 | ||
| 5 |
The plot uses x = 1000/T (K⁻¹) and y = ln(σT), with T in kelvin.