Ambient Air, Emissions and Noise Monitoring: methods, field practice and data quality.
ENVIRONMENTAL MONITORING / 05

Air and Noise Monitoring

Air and noise measurements are highly dependent on location, operating conditions, meteorology, equipment setup and the purpose of the assessment.

1. Ambient air monitoring

Define the pollutants of interest from the source inventory, fuel/process information, health or ecological receptors and applicable standards. Potential parameters include particulate matter and selected gaseous pollutants; the programme should not assume every pollutant is relevant at every site.

Locate monitors to represent the intended receptor or background condition. Document inlet height, nearby obstructions, roads, local sources, land use, meteorology and instrument configuration. Record data completeness, maintenance, calibration and invalidation periods.

2. Stack-emission testing

Before testing, review the process, fuel, control equipment, stack geometry, sampling ports, access and safe working conditions. Representative stack testing may require defined traverse points, velocity/flow measurement, temperature, pressure, moisture and pollutant-specific sampling trains. Isokinetic sampling is important for particulate methods where required.

Record process load and control-device operating state during the test. Results may need conversion to a specified dry/wet, actual/standardized or oxygen-corrected basis. Never compare values until the reporting basis matches the applicable limit.

3. Noise monitoring

Identify the objective: workplace exposure, boundary noise, community impact or source characterization. These are different assessment tasks and may use different instruments, positions, time weighting and averaging periods.

Use a suitable sound-level meter and acoustic calibrator. Record instrument class, calibration checks before/after measurements, microphone position, height, weather, background events, operating equipment and measurement duration. Select metrics such as equivalent continuous level or maximum level only as required by the applicable method.

4. Meteorology and context

For outdoor air and noise assessments, record wind speed/direction, temperature, humidity, precipitation and other relevant conditions. Note unusual events, nearby construction, traffic, intermittent sources and plant operating changes.

5. Reporting table

Station / point Objective Parameter / metric Method / instrument Operating and weather context Result

Air-quality, stack-testing and noise requirements vary by jurisdiction and assessment purpose. Use current prescribed methods, competent personnel and appropriate safety controls.